DESCRIPTION

 

The Respirator's medium size filter canister have plastic lightweight housing.  Their inner structure consists of two different parts:

 

1.  Activated carbon which removes the contaminating gases and vapours from the inhaled air in a physical and/or chemical way.

 

2.  Filtering part made of a particular quality paper which removes the solid or liquid contaminating particles from the inhaled air.

 

Gas filters contains only the first layer, particles filters only the second one and combined filters contain both.

 

THREADED CONNECTION:

 

40  1/7" cord thread, according to EN 148-1

 

USE

 

The filter canisters can be used if the concentration of the contaminants in the air is not higher than 5000 ppm (0.5 v%) and the oxygen content of the air is 17 v% minimum.  The filter canisters may not be used if the contamination present causes immediate death or permanent injury of health (IDLH).

 

STANDARDS

 

The technical parameters of the filters comply with the provisions the EN 141, 143, 148-1 and MSZ 15490 standards.

 

All types are CE marked.

 Gas Filters:

against solvents, organic gases and vapours A2

against inorganic gases and vapours B2

against acidic gases and vapours E2

against ammonia and amine derivatives K2

against organic and inorganic gases and vapours AB2

against organic and inorganic, acidic gases and vapours as well as ammonia ABEK2
Particle Filters:

against airborne particles solid or liquid and bacteria

P3

Combined Filters:

against organic gases/vapours, airborne particles and bacteria

A2P3

against inorganic gases/vapours

B2P3

against organic, inorganic gases/vapours, airborne particles and bacteria

A2B2P3

against organic, inorganic, acidic gases/vapours, ammonia and airborne particles and bacteria ABEK2P3

 